null

Frequently Asked Questions

 ERROR SIGNALS THAT DISPLAY ON YOUR UNIT

Understanding the error codes that display on the Indoor Unit.

  • E0 - (Common at Start Up) - Lost Communication between Indoor and Outdoor Units (If at initial startup, check for miswiring or broken or disconnected Cable #1, Leftmost of 3, may be labelled differently)
  • E1 - Indoor Temperature Sensor Fault
  • E2 - Indoor Pipe Temperature Sensor Fault
  • E3 - Outdoor Pipe Temperature Sensor Fault
  • E4 - Refrigerant System Leakage or Fault
  • E6 - Malfunction of the Indoor Fan Motor
  • E7 - Outdoor Air Temperature Sensor Fault
  • E8 - Outdoor Discharge Temperature Sensor Fault
  • E9 - Outdoor IPM Module Fault
  • EA - Outdoor Current Detect Fault
  • EE - Outdoor PCB EEPROM Fault
  • EF - Outdoor Fan Motor Fault
  • EH - Outdoor Suction Temperature Sensor Fault
  • FX - Advanced Troubleshooting Codes - Contact Tech Support for Assistance
  • P4 - Compressor Overload (If at initial startup, check that refrigerant valves are open)

WARNING SIGNALS ON THE DISPLAY

  • CL - Clean Filters