Description
Universal hot surface ignition module replaces multiple field installed hot surface ignition modules supplied by Honeywell, White-Rodgers, Robertshaw and Johnson. Uses a 120 VAC igniter. Includes cross reference, instructions, and accessories for easy replacement.
FEATURES
- Replaces over 800 White-Rodgers, Robertshaw and Honeywell hot surface ignition models.
- For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or equivalent).
- S8910U 3000 Series has LED status indicator and microammeter ports for easy trouble shooting
- For local (single rod) or remote (dual rod) rectification type flame sensing.
- Contains easy-to-use cross reference and instructions plus the accessories required to replace the existing hot surface ignition module.
- Provides one or three ignition trials (four-second or seven-second trials) per call for heat.
- Field selectable number of ignition trials and trial time based on unit being replaced.
- Igniter warm up time: 7 (12 seconds second and third trial), 17 (27 seconds second and third trial), 34, or 45 seconds
PRODUCT SPECIFICATIONS
Dimensions (in.): 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. long | Ignition Sequence: The number of trials for ignition and trial time is determined by the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and one ignition trial. |
Dimensions (mm): 133 mm high x 103 mm wide x 49 mm deep | Typical Gas Control: VR8205, VR8305 |
Electrical Ratings: 24 Vac | Type of Gas: Natural or LP |
Frequency: 60 Hz | Flame Sense: Single Rod or Two Rods |
Approvals, CSA: Design Certified | Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270) |
Tradeline Value: Tradeline | Ignition Trials To Lockout: 1 or 3 |
Flame Failure Response Time (sec): 1.5 sec. | Lockout Timing: 4 sec. or 7 sec. |
PrePurge: 32 seconds | Ignition Trial Time (sec): 4 sec. or 7 sec. |
Ambient Temperature Range (F): -40 F to +175 F | Maximum Valve Load @ 24 Vac (Amps): 2A |
Ambient Temperature Range (C): -40 C to +79 C | Typical Ignition Hardware: Norton 201, Norton 271, Q354 |
Ignition System Type: Direct Hot Surface Ignition | Between Trial Time (sec): (2) 96 sec.- 3 trial mode only |
Disclaimer
Failure to follow instructions carefully can result in injury or cause damage to the product. Check the ratings given in the instructions to make sure the S8910U module is suitable for your application. The installer must be a trained, experienced service technician. After installation is complete, check out operation as provided in these instructions. Acr4sale is not responsible for how the product is installed.