Description
Overview
Combination gas control for use in 24 Vac gas-fired, standing pilot appliances with capacities from 30 to 300 cfh.
Features
- Control includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
- Compact size.
- Provides two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends.
- Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
- Meets codes requiring dual safety shut-off.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
- Compatible with ECO connector.
- LITE-RITE (OFF-PILOT-ON) lighting sequence.
Product Specifications
Application | Single Stage |
Dimensions (in.) | 5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. deep |
Dimensions (mm) | 135 mm high x 104 mm wide x 69 mm deep |
Includes | Natural to LP Conversion Kit; One 34/" x 1/2" reducer bushing |
Item Type | Product |
Mounting | 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. |
Frequency | 60 Hz |
Approvals, Underwriters Laboratories Inc. | UL Component Recognized MCCZ2.MH5323 |
Approvals, Canadian Standards Association | CSA International: 112395 |
Electrical Connections | 1/4 in. quick-connect male terminals |
Voltage | 24 Vac |
Operating Temperature Range (F) | 0 F to 175 F |
Operating Temperature Range (C) | -18 C to +79 C |
Body Pattern | Straight-through |
Opening Characteristics | Standard Opening |
Pressure Ratings (psi) | 1/2 psi |
Pressure Ratings (kPa) | 3.5 kPa |
Inlet/Outlet Size (in.) | 1/2 in. x 3/4 in. |
Pilot Gas Outlet | Compression fitting for 1/4 in. OD tubing |
Pressure Tapping | 1/8 in. NPT with plug |
Type of Fuel | Natural (LP with included conversion kit) |
Capacity (kBtuh) | At 1 in. wc p.d.-- 190,000 BTUh: 30,000 BTUh minimum: 290,000 BTUh maximum Natural Gas |
Approvals, Australian Gas Association | 4717 |
Pressure Regulator | Standard |
Pressure Regulator Setpoint (in. wc) | 3.5 in. wc |
Pressure Regulator Setpoint (kPa) | 0.87 kPa |
Ignition Type | Standing Pilot |